Jump to content

EL NINO77

Full Member
  • Posts

    1,337
  • Joined

  • Last visited

 Content Type 

Forums

Detector Prospector Home

Detector Database

Downloads

Everything posted by EL NINO77

  1. ...in this test I also tested the coins, small and medium size coin,,....50eurocent at a depth of 38cm in the ground, and 1 Polish grosz-15mm -1.65gram coin-at a depth of 29cm.in the ground. and the big coil detects these coins with a good signal, tomorrow it compares to 15x12" coil and 11" standart coil on these coins...
  2. It's lead ... And I increase the sensitivity from 20 to 22 - 15x12 "coils - Is similar or exceed the range of 11" standard coil ... Tests in terrain at 0.05 gram gold O - segment at a depth of 10 cm in the ground I show it - when raising sensitivity 21-22 to -11 "standard coil-with sensitivity 23,24..to 15X12 large coil..this coil is sensitive ..., works well on high sensitivity...tested in programs Park 2,recovery speed 4-5 is optimal-in test..,
  3. short-coil airtest for small things, program Park2- sensitivity 20, recovery speed -4 ...,weight in grams,diameter items in milimeters, distanse in centimeters..
  4. 11 "standard coil-506 grams, .. 15X12" coil-660 grams, 6 "coil -303 grams .. -15v12 coil-is of its size, very light., that sounds very solid .. I have measured the weight of the coils...now test for very tiny items...
  5. The first control airtests indicate that the 15x12 coil is equally sensitive to small items like gold earrings, or small 13mm -0.50 gram silver coin Denar ... the middle, and the big coins are deeper - programs Park1, Park2 for recovery speed 2 and 4 and sensitivity 20... The impression of the big coil has more than the same reach of these two recovery speeds 2 and 4-as compared to the standard 11 "spools there were more differences .. tomorrow I will make a test for the smallest items ... and then tests in the ground...
  6. I have a first look at the 15x12 Equinox coil. the exact size of the coil without the cover is 30.7cm x 38cm, the weight of the coil with the coil cover and the cable is equal to 660 grams .., mounted on the shafte golden mask is light-so it's okay ...
  7. I like to see the 13 "-13.5" coil....somewhere I read that for 50eurocent coins it gives 5cm more, and big coins is more ....I'm curious., know how the big coil will detect all coin sizes ...The weight of this 15x12 coil should be about 650 grams ...- it's a light coil...
  8. Maybe I'm lucky, -the" big" coil on the Equinox is on my way home to me, when it's a weekend so I get it on Monday 15,
  9. .For the 2D nailboard test, the size of the coil has a significant effect on the results ... 11 "I have bad results in the 2D nailbord test" Coils 9 ", and I have less than good results in this test ... In my the 3D-deep separation test, coils Under 9" they have bad results and on the other hand coils 9" and more have good and excellent results in the 3D test .., - here is also the height of the coil above the nails, most of the detectors work well from 0-15,20 cm above the nails, except is Tecnetics G2- 13 "ultimate - the 0-20cm does not produce a positive signal signal, it starts to pass such a 3D test and at a height of 20-25cm above the nails with a very high separation is good for detection in winter ... when it's snow-...Detectors in my 2D naiboard test and 3D test: Whites SpectraV3 -4x6" ,6x9"eclipse,8x6 "sef, 10"dd whites,12x10"sef,6x10" mars sniper coil,,...Teknetics G2 - 3.5x 6.5" nel snake ,11"dd ,13"ultimate coil,..Golden mask coin killer 15khz-5"spider,9"spider coil,.... Rutus Optima- V.2-16 khz DD23CM, DD29cm coil, rutus Argo V.3 6.6khz..- DD29 cm coil,.... If you are testing the detectors in the nailbord test, you will notice that almost all detectors have the problem of passing 4th in coin position number 2 ... detectors with fast reset recovery delay do not keep, Whites Spectra V3 with recovery delay setting 45 or more it goes very all right.
  10. I have already ordered 15X12 "coil .. should be available from 15.10.2018 .., price is reasonable ... 265,.. euro.
  11. https://www.minelab.com/eur/accessories-1/by-detector/equinox-series
  12. Carl, .. I read, ...so is the development of a multi-project ...We believe that a time frame is needed for such a product development...
  13. If the multifrequency is sufficient to shift the work channels, it can well eliminate the EMI, and if it's not so good enough to use a smaller coil, which is mostly EMI-resistant, the other option is to use a program that is less disturbed, and and then degrade sensitivity ...
  14. Today I am in a test to eliminate Iron .. also came with Equinox 800-6 "coil several 0.17 pellets with ID 3 and one 0.22 with ID 4-5 ...
  15. ...Today I was passed the Equinox 6 "coil on my Carbon Telescopic shaft, on my" clean terrain, and I started Test 1-"determination of Iron" to compare the work of the Park 2 main program and the iron control of the Beach 2 program stored in the User profile .. at high sensitivity 23 .. I compared the signals with ID 15-17 before digging with a fine iron tone, which, after checking in the Beach 2 program, clearly pointed to id -6 and the pure iron tone ... which after the excavations turned out to be old nails ... Another comparison Test2 -"identifikation nonferous" was found in the Park 2 signal program with positive IDs with a bit of iron signal that would be in line with the Beach2 ID and then dig it ... I dug a few pieces of colored metal .. so I have the impression of reliably getting enough of this test. .My program Park2 settings: sensibility 23, allmetal,recovery speed 7,iron bias 0-1,. For control Iron- In user profile: program Beach 2,sensibility 23, allmetal ,recovery speed 8, and iron Bias 9.. It's during the test 1. - the nails in the ground - in Park 2 I have been trying to reduce the sensitivity from 23 to 15 to lower to get some better signal on iron and less signal for colored metal .. - but it was also not ideal. Continue in 2 tests to see from program Beach 2 did not have the problem to show a good ID for such a small shot-pelet in the ground ..Photo on left side test1- determination of iron-is pulled out of iron ... on the right side Test 2 on the truth of identification of non-ferrous metal ...3 pellets and piece of metal ..
  16. Another step forward - how to use the Signal probe function to repair a coil that is out of signal tolerance ... I degraded the signal value below half the value and removed the overload ...
  17. ... in the test firmware for Equinox... it was also possible to set the pinpoint power ... I would appreciate the possibility in another update ...- to set it up as a very weak signal, or not on a very deep coin ....
  18. So, and the telescopic carbon shaft is home. The Equinox is 57 cm long for comparison,the weight is 1224 grams of 6 "coil..
  19. I also found some coins in the iron that I had a partial iron signal and ID 16,17 to 21,22 - but I decided to dig it after the first such digged coin - I'm more careful ...., I can find me more this signal from the coin ...- I know definitely need to feel more audio signal Equinox ...
  20. The Iron Bias setting also influences: 1.Of the detector frequency used, or the multifactor program weights, 2. the set recovery speed ...,. 3 Detector Discrimination Used. and also 4. detector sensitivity adjustment ... Now you can select -A: Do you want to increase the separation and unmasking of the detector in the iron? .. or B-do you want to discern iron-plated bottle cap caps? ... If you want to maximize the separation-A give the frequency, the multifrequency program type Park 2, the high recovery speed, the less or no dyscrimination, and less the sensitivity of the detector ... If you want to determine what is a ferrous waste- B, use a low frequency, a low power, low-frequency Beach 2 program to scale!, increase the iron bias to the maximum !,recovery speed high 7-8-!-its less sensible for, tini,or plated metal.. , increase the discrimination setting- !, and decrease the sensitivity...
  21. ... it's 28mm , .. I have a golden mask with these carbon shaft ... such a set to adjust handle to shaft Golden Mask is for sale ...I already ordered one .. I write more about it .. when it comes ..
  22. On my modified carbon rod I used a 1 Nylon pad to define the size of the coil attachment .. it is better than the thicker rubber base ...
×
×
  • Create New...