Jump to content

EL NINO77

Full Member
  • Posts

    1,337
  • Joined

  • Last visited

 Content Type 

Forums

Detector Prospector Home

Detector Database

Downloads

Everything posted by EL NINO77

  1. ...Idea is good...., glas- display,-headset - detector, application, ..."Piochon" not .. good idea... better idea - ist have pinpointer with TID and gps tracking and writing good finds.... But it's not XP info...
  2. Equinox is not in any case castrated Spectra, it's a high-power multifrequency metal detector ...
  3. Deus V6 ?....yes, it's false information ...
  4. It's not necessarily, for example, on sensitivity 20, on the contrary 15X12 "coil works at me in a wide range of Recovery speed 1-7 good signal- whit ID,,and best signal - recovery speed 4- better... than 11" standard coil at Sensitivity 21 -It works well on the recovery speed range 1 -... 4 whitID,max5 .. to recovery6,7,8 is weak signal - at very deep targets - coins 50eurocent to 37-38 cm= 15".. in the ground .. picture-rate mineralization ground..in Test...
  5. Yes, setting recovery speed to impact on Ground balance the Equinox, keep in mind that recovery speed is more or less perfect electronic replacement of coil sizes .. -to a certain extent...
  6. Spectra V8...The effective frequency range of the multifrequency is about 1: 8, so I need 2core sequential multifrequency power transmitting unit with 2x range working together, 1.5khz-12khz and 12khz-96khz.., and user programs with different use of these frequencies ..resistente EMI ... Tx Bost...Display such as the Spectra and the two-digit TID -like CTX- which uses data from 2 core...Waterproof...weight 1.2-1.4 kg .. the picture is the TX wave for Spectra V3 -even with this detector, there is a great possibility of improvement...
  7. ...Today in deep tests 3 Equinox coils on Park 2 I found that I changed very strongly the values of phases at Ground balance ,,, - it was shown to happen when changing recovery speed .., so I checked it-tested: program Park2, sens 20: ..recovery speed1 -number Gb-47, ..recovery speed4 .. number Gb-37, ..recovery speed 6 ..- number Gb-32, ..recovery speed 8.-number Gb-22 ... So I recommend to change the recovery speed,.. make a new Ground balance...
  8. Yes,.... the 15X12 "equinox coil is deeper than the 11" standard coil, it's like more + 2 sensibility, and it's most visible at high recovery speeds ... where the 11 "coil does not even increase the sensitivity ...Today I tested all 3 Equinox coils on the Equinox 800, plus other coils on the Whites Spectra V3 ..
  9. Praying Whites to give us our best innovated detector ...Spectra V4,Spectra V5...
  10. ..that is a crystalline pyrite from Navajun-Spain-from times when I did not have a metal detector ...,also nice times...only hammers and mowers..
  11. I think the automatic noise canceling could take 2x-3x longer, better would eliminate the non-linear EMI ..
  12. One of the possibilities of comparing the current and the new firmware is to locate 10-20 suspected signals in the terrain, and then verify them on another firmware ... at the same time...
  13. yes, try also to shut down Allmetal, it will also help you, rumbling when you are under electrical lines...
  14. If you ever find yourself happy with automatic noise cancel, try also manual noise cancellation to remove Emi, sometimes also help if at noise cancel hold the coil about 10-15cm to the ground ... What helps ... is the low recovery speed...As for the elimination of EMI in the Whites Spectra V3, use a smaller coil but still the depth of the coil-Mars sniper 6x10 ", 5hz band filter, Txbost ON, and Modulation audio - to 1- max2 ...
  15. Yes,, Garrett ace 400i is a good detector, compared to 350-plus numeric ID,... and Iron Audio...-better separation, and identification of iron, and my observations are sufficiently sensitive and deep ...
  16. Thank you for commenting, and an outstanding look at the work of the 3F multi-frequency Whites Spectra - Nailed....First of all, to say that the test video does not come from me-is from scannerguy1968... but it shows the work Whites Spectra V3i on targets in the terrain, using 3F signal analysis on the targets - which I also use - 3f pinpoint,3f spectragraf and 3f signagraf - especially in the weak, or mixed signals - which do not provide a stable ID, but in the audio signal they give partial tones to non-ferrous metals....in this case the use of Spectragraf shows the prevalence of the signal on non-ferrous metal, so I dig it ...
  17. We will see what Minelab is doing in the right direction of the coils .. Many Equinox users - many demands on the size of the coil - other manufacturers can also enter the market ... the multifrequency coils ... now on the test this multifrequenci coil for the Whites Spectra V3:
  18. Small 5 "and 3.5x6.5" coils can be closed with epoxy and keep low weight ... Coils 5-6 "x9X10" and 6X8 "require different design to maintain low weight. Equinox is also 6 "the coil very deep detector .., so how to close the coil for gold prospecting I would see something like 4.5-5"x8-9 "...The 6X10 mars sniper coil is sensitive and very deep coil ... to its size... reach similar to 6X8 -sef coil ...
  19. Better 70-% use the 15X12 coil on the detector,..how to let the big and heavy coil fall in the cabinet.Important is that 15X12" is as sensitive as 11"standart coil..and it has more depth...
  20. ...the carbon rod can lose weight by 100-130 grams - on the side of the coil it hangs on the detector's construction, - 1 long bar is used. assuming one is the length of the rod instead of the middle and the lower rod. ..- the next thing is the battery weight- the use of a Li-ion battery can lose weight by 150 grams - and if the battery is built... even more. 3-piece carbon telescopic shaft ..- is optimum .. ..I believe the Whites are working on it...
  21. I do not have to play video - because I have it at home from my observation is deeper. clearly, you can wait for some of the test videos ...
  22. I think that for many detectors the 15x 12 "coil will work, most of the time as the main coil... That coil i have the sensitivity and reach of very tiny objects, but it also has a lot of reach for coins and medium and large objects. Is a control comparison of 15x12 "and 11" coils, in program Park1 and Park2 on sensitivity 20 and recovery speeds 4:in a moment I will publish the results of the airtest...
  23. Personally, weighing the Equinox even on a 15x12 large coil as well ... ... I have compared a standard 11 " coil and big 15x12" coil - at 50 eurocents buried at 38cm in the ground. Test Field is uphil - so detecting that coin from different directions its more difficult ... here the standard 11 "coil had a problem with the detections - it did not give any good signals, or repeated, but .. one-sided signal .., so a large coil gave good signal from ID from all directions .. , Tested on programs: Park1, Park2, Field1, Field2 ... In my opinion, Park2 and Park1 pronouced beter signal in sensitivity 23-24, than Field 2 and Field 1 at the same sensitivity. In each program I tested the sensitivity and range of the coil on 3 small items in the ground: golden O- segment 0.05 gram of gravel on 10cm in the ground.13.5mm denar drained to 23cm in the ground, and 13mm silver earrings buried on 20cm .. programs Park2 and Field2 gave signal and ID to all 3 small objects on the sensibility 22, -its the excellent sensitivity and the range for big coil..... The 11" standard coil which takes it in sensitivity from 21 ... Park1, and Field1 no pronounced signal at golden 0.05 grams of the O-segment can not be seen sometimes in some situations again ... all of the first tests ..the cross indicates the position of 50 eurocent, 3 plastic collars position 3 of small objects in the ground...
×
×