Jump to content

EL NINO77

Full Member
  • Posts

    1,337
  • Joined

  • Last visited

 Content Type 

Forums

Detector Prospector Home

Detector Database

Downloads

Everything posted by EL NINO77

  1. With the optimal VA setting: f1.7.5 Equinox 800 Park 01 program ,Pic1 Equinox 800 Park 02 program ,Pic2 Equinox 800 Beach1 program Pic3 Whites Spectra V3 -3F multi,Pic4
  2. Spectra X7 ...... .... I like Spectra... ., the X-extra% performance, and the number 7? - I have more meanings...
  3. Whites and SpectraV3,V3i.. it's timeless metal detector and pattern for other detectors.... he got into a certain disadvantage at the beginning -that had to refrain from being able to simply update the firmware ...Because updating detector software makes it possible to quickly and cheaply eliminate the deficiencies, even greatly improve work detector detection and also flexibly respond to market demands-and dramatically extend the lifetime of the top product-to the highest quality detection for many years ...
  4. Graphs Recovery speed its correct, Equinox 800 and Rec.speed 6 = Equinox 600 Rec.speed 3..
  5. Thank you for replying, Daniel .., I have gotten from the mineralized terrain / 4-bar Tek G2 / it is important to set the recovery speed of my sweep with a coil, rec speed 4-5 is good, recovery speed 6 is less deeper and also requires faster sweep by the coil to get the signal.
  6. ...Multifrequency is a more versatile technology-the operator has the ability to work very well in a wide variety of terrain conditions than a 1-frequency detector.. .... Determine .. Another detector development will be directed to Bi-Multifrequency Detectors ... 2 or more -different weighted multifrekquency programs will work...at one time...
  7. DanielTN .. does not limit your recovery speed setting to Equinox 600 and a 15x12" coil in your strongly mineralized terrain?
  8. Iron bias - Minelab Equinox ,,is a bottlecap reject -at Whites detectors, ...such as Silencer -XP Deus, ORx, Gold max power, detectors ... and settings - Mask at Rutus Detectors ...Personally, I've been influenced by the Iron bias settings ...on the detector work... first seen by my detector Rutus Argo , and Whites SpectraV3 .. If you want the maximum separation and the response in the iron, and for the work in the mineralized earth,and depth ...and the partial iron-non-ferrous signals to use Zero or Low iron bias settings-0-1-or 2-max..Setting the Iron bias-the signal filter affects not only the audio signal but also the correct identification and discrimination - TID, so do not underestimate the setting... Even when working on small,sniper coils... For lesser iron infested conditions, or specific conditions, you can adjust the setting to the Iron Bias from 3- to7-8...its compromise..you get less false signals from the iron, and average separation..-You can make this setting yourself over some signals directly in the terrain. Iron Bias 9... it very much suppresses the separation ... but I recommend saving it to the a User program to compare Signal ...
  9. I use beach 2 as a user-program for signal control..
  10. Yes, you are right, there is everything ... even when it comes from the locality .., Meteority is for me a new theme, sometimes there is some hot-rock, and I always tried to eliminate them .. I'm interested now. .. Fredmason ....Thank you ..
  11. ....I think of the main role and the prevalence of marketing ... which at that time was more important than the best technical parameters and detector options. -The next conclusion is that most of the detectors wanted to use a simple and reasonably efficient detector without long adjustment...Dfx and Spectra have been technically over time.. Now new detectors have to offer better technical parameters of more frequencies in one coil... Of course - the influence of certain frequency on the sensitivity, range, ..on a variety of subjects -and especially iron unmasking, .....it's worth it . Today, the detectives themselves are now more experienced, setting up detectors ..., and the Internet and Yt videos allow for a simple understanding of the setting-and their impact on detection ...
  12. ... Is Fisher Gold bug-pro / TekneticsG2 a suitable meteorite detector..?
  13. http://www.geotech1.com/forums/showthread.php?24893-Minelab-Equinox-800-Frequency
  14. C-D....I'm wondering one question about the DFX setting. Is there a range for those settings on Dime?Can you get a 11 "airtest on Dime?
  15. Equinox programs have their logic.. : Test-tiny pieces Alu foil-and coin umasking..-using low sensitivity.. ...1. test small non-ferous pieces and coin , 2.test small ferous pieces and coin... Unmasking...in programs -using low sensitivity...
  16. To...rled2005...try the Geotech1 forum, there I can help....
  17. .The test field is not a bad idea, I have a single 4x4 meter square to quickly retest the detector setting, and also the coil and EMI resistance. It's located in my fruit garden ... 35X35metres long=1200 squares metres and polluted with old iron, and practically cleaned from non-ferrous metals this is my 2 test ..., ... Zkušební pole není špatný nápad, mám také zkušební pole 4x4 metrů -1Test rychle zkontrolovat nastavení detektoru a také odpor cívky a EMI. Nachází se v mé ovocné zahradě ... 35 x 35 metrů dlouhé = 1200 metrů2, a znečištěné starým železem, .... čisté z neželezných kovů to je moje 2.test ..., 3. Test is my 50l ceramic rust - "Liapor" in a plastic container, - testing in high mineralized soil -4 Bar Fe3O4-TekG2-11"DD.. This very quickly revealed how to set up the detector and also the velocity sweep speed in similar conditions.... Test 3 - je moje 50l keramická hrdla - "Liapor" v plastové nádobě, - testování ve vysoké mineralizované půdě -4 bar F3O4-tekG2-11dd "cívka .. -Tato velmi rychle detekovala správné nastavení detektoru a také rychlost otáčení cívky za podobných podmínek ...
  18. I did this test on the picture - the ring is under the nails. Detectors -and small coils ,,in gold ring - Nail test:...base - mineralized ceramics "Liapor"- 4 bar Fe2O3 - Tek. G2-11DD" coil .. Equinox 800.-6"coil ,p. Park2 ,IrB 0-1,sens 15-20,rec.sped4-6, ... Yes-4way-100%passed...slightly faster sweep coil.. Fisher Cz3D-5"coil. disk0, sens 1-6 ,exhanced and salt,- No-0%way passed... Teknetics G2- 3.5x6.5" -nel snake coil: sens 70-100,disk 31-33, Yes 4way-100%passed, Disk on 33-slightly faster sweep coil...,, Disk on31 normal ,and slightly faster sweep... Garret Ace400i -4.5"sniper coil- allmetal,sens 1-8, -4way -No passed..., from 1-2 sweep directions -in Sens 5 bar,,a timely signal at the edge of the coil.. Tesoro Mojave-7"-precision coil, Disk in 1/2 foil- on the letter " I "-on Iron, sens 2-5, .. Yes 4way -100% passed ...-slightly slow sweeping the coil... Golden Mask Coin-killer 15khz -5" spider coil :disk on1.5. sens 1-8..1-2tone, Yes..4-way 100% passed.. -Way n.3 slightly slow sweeping the coil.. Whites Spectra -6x4" shooter coil : 1.F-22.5khz, program Hi-pro ,12.5hz-high ground filter, recovery delay 25-30 ,RxGain-5, DS-92 ,bottle cap Off.,- ..Yes 4-Way100% passed.. -slightly slow, sweeping the coil..... At 3F multifrequency-2 way occasional signal, at 1F 7.5khz-no signal... The tests will continue-try using 6X10 ", standard, or 13" coil,... Later I try to place the gold ring under the nail in this test...
  19. I think it's a good 2D and 3D test ...Test 1:.. The 3gram gold ring on the top between the nails is not a problem for a lot of detectors - sweeping, from 4 directions. Test2: 3gram gold ring under the nails-well preverts the ability of the detectors ....
  20. Amergin.... I have devoted some time to this problem to test : On Park1, Park2, and Beach2: I have set the usable setting: On coarse iron ... you have to set the Iron Bias to a minimum of 7-8 to remove phantom tones .. and from the high recovery rate 6-7,8 settings, keep the separation acceptable to a small 6 "coil. option1. Program Park1, sense 15_20, iron bias 7, recovery speed 6-7, discrimination accept -3do40, option2.Program Park2, sens15-20, iron bias 7-8 .., recovery speed 6-7, discrimination accept -3do40 .., option3.program Beach2: sens 20-23, iron bias 7, recovery speed 6-7, discrimination accept -3 to 40 ...
  21. Upgrade what the Whites its well ,: 1.3F Multi-Frequency - 7-10 Frequency-Weighted Programs -by Type of Search... 2.Spectra display-upgraded graphics display TID.-spectragraph-signagraf-a 3f.pinpoint together on 1 screen,, 3. "User program" to pinpoint.-to compare the signal ..in diferent programs.. 4. Deep and accurate - TID -Whites type 190 numerals 5. Waterproof 3-5m .., lightweight .. and compact ..,li-ion batery.. 6. The box under the armrest - let's leave it - more compact - it's" Whites metal detector* ".. 7. Multifrequency Coils - with electronic balancing I-B stabilization - like with coils MX Sport..
  22. "Lunch free"- in detection technology does not exist....the, high frequency,...high gain, and sensitive detectors will still be very sensitive to corroded iron, and the small coils has increased these properties ..you still can slightly reduce the sensitivity and the results will be good...I use to control the small 6 "coils of some suspicious signals User program low frequency program Beach 2, and there already these signals into pure iron.ID....-2, -6..remember the 6 "coil is also in Beach 2 - a sufficiently sensitive and deep coil....using sensitivity 20-24..
×
×
  • Create New...