Jump to content

EL NINO77

Full Member
  • Posts

    1,337
  • Joined

  • Last visited

 Content Type 

Forums

Detector Prospector Home

Detector Database

Downloads

Everything posted by EL NINO77

  1. Not to forget to evaluate the 7 "CC Precision coil: It's also a great coil for the Mojave .. it still finds and separates the good things from the iron. From the sensitivity set to max,.. its range in the airtest: is almost the same with the 6x8" SEF coil set to Sensitivity 5 ... Therefore, even the Sef coil when set to Max sensitivity has a 1-2cm better reach even in the mild and heavily mineralized ground. But if you detect in a very strong mineralization.... still use the Tesoro mojave some DD coil - will allow you to effectively and reliably detect under heavy conditions.
  2. To prepare 7bar BlackSand use 75kg sand and of 3 Kg=6x 0.5kg bottles technical Magnetite. But I will still check it on Teknetick G2 and 11 "DD Coil, and also on the Whites SpectraV3 detector, there is a Ground probe on 3F multifrequency to set the minimum RxGain-1 = from 13% -26% mineralization according to the type coils.. I will add a few more comments from the test: In medium and high 4bar mineralization enough to forgive the setting of discrimination and the movement of the coil, At the extreme high 7Bar fe3O4 blacksand mineralization : the best results you get by setting the discrimination on I-Iron... and also adequately reduce the speed of sweeping coil.
  3. Tesoro Mojave test update and 7 "CC precizion and 6X8" DD SEF. As I wrote the coil DD in all the tests still had a little more about 1-2cm deph, so here only write coil 6x8 "DD Sef Coil.. Mojave Test Coil 6x8 "DD: 1. Hammered Coin Parvus: air-test 13.5cm 4Bar Fe3O4 liapor test 10.5cm 7bar Fe3O4 BlackSand test -7.7cm 2.Au heart: air - test19cm 4bar Fe3O4-liapor test 13.5-14cm 7bar Fe3O4 blackSand test -10.5cm 3.Au ring 3gram: air-test24cm 4bar- FE3O4 liapor test 18cm 7bar FE3O4 BlackSand-13cm .. 4. 1FT SILVER Coin: AIR-test 23 cm 4BAR Fe3O4-Liapor 18cm 7BAR Fe3O4 BlackSand test-13cm 5. GOLD brick 1GRAM: AIR test-16cm 4BAR Fe3O4 Liapor Test 12-13CM 7BAR Fe3O4 BlackSand Test-10CM .. The results I have achieved in the tests show from the Tesoro mojave range on the set objects with a percentage equivalent for some type of mineralization terrain where:. Airtest means 100% reach .. . At 4bar Fe3O4 strongly mineralized terrain we reach only max75% -77% of Airtest reach. At 7bar Fe3O4 extremely strongly mineralized BlackSand terrain we get only a max of 55% -57% reach in Airtest .. 7Bar Fe3O4 "Blacksand test" 4Bar Fe3O4 Liapor test"
  4. LE.JAG ... I would have one question .. is it possible to market AQUA-Pulse and TERRA-Pulse in the same time period ..? Another question would be when will I start pre-orders for AQUA-Pulse and TERRA-Pulse detectors? I admit to TERRA-pulse is a detector that is personally interested in me ...
  5. Initial tests of CC coil vs DD coil on 4bar -0.4%FE3O4 strong mineralization and also 7bar-4%FE3O4 extremely strong mineralization on Tesoro Mojave .. already in progress: First observation: 1. Coil 6x8 "SEF has a little more reach 7-11% in airtest-and ground tested at low and maximum sensitivity.. than 7"CC Precizion coil.. 2. .. I was surprised by the 6X8 "SEF coil with extremely mineralized BlackSand already at the setting of the switch Ground balance to LOW ...- and is extremely silent ..- stable work Standard Concentration 7 "Precizion coil has a problem with debugging GB as well as setting GB to HIGH ..- and sweeping is a sense of cracking, and sometimes false signals from the ground. it is independent of detector sensitivity setting ... and virtually makes it impossible to detect normally in this black sand test ... 3. Practical deep tests on various subjects show a little more deep range in the 6x8 "SEF coil, and "+ " ..has a "wider" / 7-8cm / maximum signal detection window = easier and more powerful detection. On a concentric 7 "precizion, you have a "point"-to-detection window - you need to get it to the target very accurately to detect it. 4. DD Coil 6X8 "Sef Extremely Fast Separate Objects Leading Each Other Coil 7 "precizion has a much worse side target separation here. 5 .. more details about the test write later and divide this test into: A. ranges and both coils in airtest, and in low mineralized terrain. B.testing coils for deep detection on 4Bar liapor mineralization, C.Testing and reach of the same objects at 7bar Black sand -extreme Mineralization .. 6.Optimal setting of the Tesoro Mojave detector to the conditions - and the effect of the setting on the detection ..
  6. 2 tone is not just a simplified version of 50ton or 5ton - but it is similar to sound reproduction ... as with analog detectors ... you are more familiar with the details of the signal ... and -the location and the edges of the objects- in the ground- over target - here help 5-6-7..settings recovery speed ...
  7. Since I have a Tesoro Mojave 7 "concentric coil that works great ...It is not a deep demon, but it can unmask signals in a reasonably good depth even behind many Top Detectors .... I decided to buy a DD coil of a similar size to it ... which will work well at extremely strong mineralization. Finally I ordered a 6x8" Sef coil. . Because coil 7 "DD tesoro widescan is no longer in the seller's offer .. ...From my experience ...my the coil not the V-rated Sef 6x8 " on the Whites Spectra V3 detector will not separate so well in a 2D nailbord test as a round 6" coil, or 5x10 "coil .... but in practice in the field.... it will unmask nicely... Signals ..It's a lightweight coil - on the Spectrum V3, it's a weight with a coil with a cable and coil cover of = 400 grams. That's why I bought it - I needed a lighter coil for detecting in the hills and rocks.. ---------------------------------------------------------------------------------------------- When the Sef 6x8 "coil comes to Mojave, I will test it and write my observations..
  8. From my observations and also the measurement of mineralization -may say from a medium-sized 23x20cm CC coil it shows 2x a higher mineralization value as well as a 23x20cm DD coil. When comparing dimensionally larger CC and DD coils, I feel the differences will be even more important ..
  9. Noah (FL) .....Thank you for your advice,... "I ordered a 7"DD - widescan coil....I'll let you know how the coil will work in strong mineralization..
  10. If I wrote ... that minelab Vanquish will be a multi-frequency detector - that's the information that's approved by Minelab : I quote .... "Minelab wants to offer its new multi-frequency technology to the widest possible audience...."
  11. New Information.....: Vanquish will be a multifrequency detector.....
  12. From my observations Tesoro mojave - coil 7 "precizion works on setting GB to" Low "works well on 4 bar - Fe3O4 mineralization, and on setting GB to" High "here he is missing something to stable work - detection at 7 bar BlackSand mineralization ... My question N1. is - will Tesoro Mojave to set GB - "High" in such a situation ... to -extremely strong mineralization better to work on DD type coil than to its Concentric 7 " Precizion coil?
  13. Something else, .... in this 7-Bar Fe3o4 Black Sand test my optimum setting Equinox 800 on programs Park1 and Park2... was .. : 1."Discrimination" from +1 to +40 ..-you get a great and exact ID.=reading "11-12"ID -for small gold pendant its - perfect.. If you only discriminate on accepting from +0 to +40-you get too much reading or "0 ID "or "+1 ID"- for small gold pendant to mean non-accurate read ID .. 2. "Correctly set the Recovery speed 7-or 8".-very important setting .. -to make miracles At lower settings ..Recovery Speed 1-6 ... you will not get almost any number ID even at the highest sensitivity -...25 .. even if you still get the correct audio signal .. On optimal recovery speed 7-8 .. you get right number 11-12 ID and good signal..from sensitivity 15.... and it works well on sensitivity up to 25-max .. 3 ."Sensitivity ".. good signal and correct ID I got at the sensitivity of 15 I tried it on both 11 "as well as small 6" coil. What is more interesting ... Equinox correctly detected 1.2gram gold pendant up to a maximum sensitivity of 24-25 in this test. This is a difference from other detectors where you have to reduce the "Gain" or "Sensitivity" setting so that you can properly detect the 7-Bar Fe3o4 mineralization. 4. "I tested 11 "and 6" Equinox coil" - ..and found the correct Equinox detector correctly and the same for 11 "standard and small 6" coil. 5.. Another observation ... it is definitely good to change ground balance - again in such a rough terrain when changing the Recovery speed.
  14. Simon ....one of the gold benefits of the one-tonne-mode is if you have enough open discrimination still a nice ton though you are getting minus-vdi. Can it be mineralization .... Have you tried other 2 ton mode like Park2? .If the program isn't as deep as the Gold modes. It's a bit out of the way, but it has a definite ... well with gold prospectus .. Today I am at 7 bar Fe3O4 -extremne mineralization for Black-sand tests. -tested several detectors and coils between the other and Equinox ... Tested item "N.4 " was 1.2grams gold pendant about 12cm deep in Black sand. When testing equinox, I noticed a non-ferrous audio signal - which was sometimes a bit worn out ... but Vdi is almost still in the minus VDI numbers -2, -3, sometimes at 1a just occasionally jumping to the right 11-12 ID .. So I tried all the programs and the best work here was Gold Programs .. enough better audio and more correctly VDI 11-13 ... but it was still not 100% OK .. So I changed the 11 "standard coil on a small 6" coil. The signal detection work was further improved, but Vdi on a small coil was still very often on minus VDI ... So I tried to change my discrimination that I use / accept -3 to + 40 / to +1 to +40. After such a change in discrimination, Equinox detection has improved dramatically and I have been practically + VDI .. very often with the correct VDI 11-12. At the end I put on the Equinox standard 11 "coil and tried to test Equinox again on the new discrimination settings. The new discrimination setting worked great ... even on the 11" standard coil. Lessons learned from the test - in too harsh conditions, it may be too open to discriminating and allmetal has a great impact on working and displaying the correct VDI on Equinox.
  15. Metal Detection in Poland has been severely limited for the past 2-3 years .., Because it does not define exactly what is historically valuable from a common find ....- so practically you should not dig anything out of the earth ..- even when excavating common objects .... Even though there are exceptions to detectors who have special field detection permits that are not marked as archaeological sites ... So ..for the ordinary detectorist there is only a place to detect it is Beach ...
  16. I agree with Chase .., with Equinox you won't find classic ground tracking, Equinox has its own ground tracking solution ...- balancing the ground balance. Watch yt video with subtitles turned on for now, and you'll find answers to many queries.
  17. I have a"Book of Jack" -Whites Spectra V3....on your computer .. I'll try to put it here on on the forum...
  18. I registered again at Whites forum ... so I have no problem .. ...but I agree that a certain degree of smoothing on the whites forum would be beneficial for the Whites ...
  19. I wouldn't say "multitechnology" detector metal has already reached its limits - on the contrary, now this technology just begins to "reasonably" enforce and do not mean only "multi-frequency" ... Let's "surprise" by what's going on in the coming years. Coils also see a place for further development ... Sometimes the coils are supplied by the detector manufacturer - truly optimally matched to the detector ... in other cases, the detector manufacturer has consciously or unconsciously not used all the possibilities of a given metal detector - and the team has created space for other coil makers - with its "Aftermarket" coil perfectly tuned for sensitivity, separation and deeper detection depth. ..I am using enough number of aftermarket coils. The coil technology itself still has its reserves.
  20. I use a mixture of 25 kg of silica sand for 1 kg of pure Laboratory Magnetite so it is approximately mineralization is 4% Fe3O4 ... the measurements show on 7bar Fe3O4 -Teknetics G2-11DD coil. This is also the limit for many Vlf detectors, but you need to radically change the settings on them and use some tricks/in overload/ to ground the Balance... LE.JAG .. Your extremely mineralized soil at 12% and 16% Fe3O4 .. will be a big challenge for many Top detectors ... So I'm looking forward to your tests with the new Fisher Pulse detector...
  21. Certainly some positive improvements can be found: 1.Adjustable modulation of audio -... Adjustable audio gain. The advantages of this setting are just a few. 2.autotracking with positive setting +3, to + 7 offset numbers Ground balance .. 3. Change user program using the button on the front panel. 4 . Pinpoint mode with depth indicator in centimeters-inch .. 5.Allmetal mode - also in Park, Field, and Beach ...program modes.
×
×
  • Create New...