Jump to content

EL NINO77

Full Member
  • Posts

    1,337
  • Joined

  • Last visited

 Content Type 

Forums

Detector Prospector Home

Detector Database

Downloads

Everything posted by EL NINO77

  1. For example, when setting the Spectra V3 to 22.5 khz, RX gain 9 / and sensitivity Ds to 95, and 7.5hz band Ground filter., Recovery delay 70...... will be on 6x10 "Mars sniper coil ... range in airtest at: 0.02 gram 24k Gold - is 4.8cm .. 0.1 gram 24k Gold -is 11.5cm .. 0.4 gram /Fine- 37-small pieces./ 24k Gold -is 10 cm... 0.5 gram 24k Gold is 18cm.. 1.0 gram 24k Gold is 21cm.. -------------------------------------------------------------------------------------------------------------------------------------------------
  2. Whites Spectra V3 in 22.5khz ... has only an average setting of preamp RX Gain = 7 and sensitivity DS = 85 ... in the "Prospecting program", and also has Ground fIlter at 10Hz high...., rec delay 90... This setting of the detector is intended for work in more mineralized terrain.... Of course, you can increase this too conservative setting to better sensitivity values ... and increase the range and sensitivity of the detector ... You also have the option of using TX bost and you will achieve even greater range and sensitivity .. on low mineralized terrain .. As for the range and sensitivity of the frequency itself 22.5khz ... versus 14khz .. the height of the frequency is only one ... of several factors .. that affect the range and sensitivity of the detector ... I will explain it later and state the ranges of various detectors and frequencies on very small gold .. sizes 0.02 grams, 0.1 grams and 1 grams ..
  3. Update 5/15/2020 - The new Garrett Ace Apex has been announced - Details Here!
  4. Vista gold gain 30khz is a sensitive detector for gold weighing 0.02 grams ... Even on a small 5.7 "coil.., it also detects my 0.003 gold test ... The Gain control as well as the Bost function allow the detector to be set up optimally on various mineralized terrains ... If I find my notes I will write a comparison of the range of my various detectors at 0.02 grams of gold ....
  5. At home I tried Tek .G2 ..probably .test to 14V mode /10X1.4Volt AA NIMH accumulator/ ..on and I immediately compared it with the range to 9V .. I can confirm that the audible range of the detector increases ... in the test I used a small 3.5x 6.5 "coil Nel Snake .. Teknetics G2 in the test had a sensitivity of 100 .... and discrimination at 39 .. The range to 0.1 grams of gold was increased from 7cm to 8cm The range to 0.5 grams of gold increased from 13cm to 14cm .. Coin range has been increased by approximately 1 to 1.5cm ... I think increasing the reach on such a small coil is generally not bad .. Let's see how the detector on the 13 "ultimate coil in field tests will reach ... But now I can say that this 14V mode I will normally use ... The 14 volt detector works steadily .. and so far I see no problem .. in the correct function of the detector.. ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------- So I will try to use 10x AA alkaline cells that should be equal to 15 Volts Mod ... and verify that it will work properly....👍
  6. ... nothing is impossible, I heard that the Vanquish V 540 on the pre-production test software was able to tune off the red brick when turned on / if the coil was placed on the brick ... when the detector was turned on ...
  7. Teknetics G2 ... I think I have 2 separate power circuits per battery ... / Fisher / Teknetics construction solution / .. and in some of its detectors also uses 2 x 9V batteries to power each circuit separately ... / Fisher GoldBug2 / so: The circuit/ N.1/ is a separate and voltage "stabilized" power supply to the electronics of the detector itself. .The circuit/N.2/ is a separate power supply for the audio signal ... So .. at a certain drop in battery voltage, the detector will still process and correctly detect / circuit 1 / ,, but its audio output / circuit 2 / will be very quiet ... and inaudible. This is more likely to occur when detected in the winter weather ..- when the battery voltage or 9V battery drops faster under low-temperature.. According to me, the "15 Volt Tuning" power supply Mod ...for Tek.G2 may be the target of the amplification of the audio output signal ... in circuit 2 / Audio signal output / ..., while in circuit 1 / stabilized supply of detection electronics / is still secured by voltage regulator ... I'm going to have to test it myself and test it for in-depth tests ... -but, according to me, the electronics should work safely up to 15 volts....
  8. In which is better Multi -IQ? .... mainly allows to meet the "one detector setup" and very contradictory detection requirements: 1. excellent sensitivity and ... but at the same time excellent reach for very small, medium, but also larger objects in the field ... On one detection program. And don't forget the exact ID up to 90% of the maximum Detection depth .. that's based on a certain algorithm to calculate the ID from the different frequency response signals -in the Multy IQ ... 2 ... Excellent separation ,, -.... that cannot be achieved when using low-frequency 5-12 Khz ... detectors ... Because excellent separation requires at least 13-15 KHz .... detector ... and the KHZ will be higher ... it will separate the better detector in the iron. Multi-IQ can do it on 1 detection program ...- because it works in wide frequency range 7.8hz-39 Khz ... 3. ..Very good work Multi-IQ on various mineralized terrains .. ,, Why is it essential? .. here's the natural sensitivity of a detectable object to a certain frequency-at which it gives the strongest signal response. In order to understand why it is necessary to know each conductive low, medium and high conductive object has its best signal response (even 4-7X thing) only within its certain frequency range ... While on lightly mineralized terrain the detector sees even very weak signals ... and has on those weak signals excellent range .. So ... in difficult mineralized terrain detector sees only those objects that still give a strong enough signal, even though the detection range here will also be lower .. So ... All objects that give already weak signals .. I will be very weakly detectable in mineralization ,,, in the worst case their detector cannot detect ... So here multi I-IQ represents a high quality compromise for balanced signal response for detecting various conductive objects ... -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Equinox goes well with my "4x4" field test ... for a wide range of object sizes ... that are buried at boundary depths ..... The test detector has to do it on one program setting ... And it proves only a few Top detectors ..
  9. After the test of Teknetics G2 where this detector also proved well locked signal on high conductive ID .... I would not cover this capability, only for the benefit of only low frequency detector ... from my point of view it is a constructional solution of signal detection ... For example, the thing that I noticed a year ago at Spectrum V3 that if you put the ground for 5-7 cm with a few coins and the last coin will be low .. so you Spectra V3 will give signal only on the penultimate coin that has a much higher ID ... so it will look like she doesn't see the last low conductive coin here .. the detector will do this on the smallest 4x6 "shooter coil ... But if in this test you start detecting from the opposite side of the coin series -and the first coin detected is a low conductive coin .... so Spectra will correctly detect all coins .... For perfectly accurate detection, you should sweep a 2X coil everywhere ... from right to left, and from left to right. At first I thought it was a lack of a detector, but in the end I understood, that it is a constructional solution designed to lock a higher ID in mixed signals ... For Equinox, for example, just make adjustments to sowtware, to lock a mixed signal on a high ID .., and call this function and "High ID "..
  10. Chase ... I've tried all Equinox multi programs as well as Beach 1 and Beach2 .. but it doesn't help if the coil is more than 2-3 "above the targets... The only reliable option is a separate 1F frequency 5khz .. ,, .....5-6+" coil .....above the targets..... but indeed 1F frequency 10-15-20-40 khz here also will not work ... Among other things, I use 2 pieces x 23mm-5gram silver coins in this test to give a much more reliable high-conductivity signal than the US silver 10 cent / dime / coin. This test is almost about the logic of calculating the ID of a mixed signal ..., Equinox hacks the low ID of the signal ..., Spectra V3 and Teknetic G2, even though they have a smaller coil, have a major disadvantage in sensitivity to high conductors ... it gets stuck in a mixed signal on a high ID ....
  11. Sube ... if Equinox worked the same Ctx on mixed various conductive targets .... it would be quite possible that it achieved comparable separation results with Ctx ... Here is more about detection logic .. Ctx and Spectra are optimized for the "American style" of the cherry picker park program ... this means finding interesting and well-targeted targets among aluminum and other waste ... Equinox is an excellent "Old world style" unmasker and is optimized ..... to detect any non-ferrous signal in the amount of iron waste ... while maintaining good identification even for non-ferrous things .... because small hammer coins start from the number 5 ID and more ..So here in Europe, for example, we dig up almost everything .... what the number 5 ID and more ... Of course, "American style - New world ..." and "European style - Old world" of detection has of course its advantages and disadvantages ... I think it is good to use both detection styles according to location, and detection conditions .. and it would be good if Equinox could exactly optimize for both detection styles ... Old European style .. Some old coins have really pretty low ID ..
  12. Sube ..... Equinox will work in this test on a single 1F frequency of 5khz ... ,, and you can lift the coil to a level of 5-6 "and possibly more inches if using a small 6" Equinox coil in the test. Multifrequency programs ...themselves will work well - right up to coil height 2-3 "above mixed targets... / Park1- up to 2"... / Park2 - up to 3 "/ .. Recovery speed used in the test was 3..., but I tried to use lower and higher recovery sped .. recovery speed in this test does not significantly affect the results, in this test is almost one logic of detector evaluation for such a mixed signal .. Setting Iron Bias/ in multifrekvency programs/... also has no decisive influence on the test result ... the only exception is setting Iron Bias to a maximum of -iron bias 9 ... where it begins to dampen the received mixed signal strongly.. ------------------------------------------------------------------------------------------------------------------------------------------------------------- I also compared Whites Spectra V3, and Tek. G2 ... on small coils ... Spectra V3...... in 3F multifrequency-/Best data../., it locks high conductors well even if the coil.. is very high above the mixed targets ,,, Teknetic G2 is also good enough ... All the detectors in the test were done with the correct Ground Balance .. Testing was performed on 4 -bar Fe3O4 .... mineralization...
  13. Garrett Apex ... Zaujalo ma toto: „Nová technológia“ .... takže čakáme na ďalšie video .....👍
  14. I think it will be new models of the class: 1. new GPZ ...detector 2. new GPX ...detector 3. new CTX detector- double-digit multi-IQ "ID".... , on.. / 3khz-30khz / technology... 4. new Equinox model / EQ1000 /...- double-digit.. multi-IQ ID? , on .. / 5 khz-40khz / technology.. 5. new Gold detector model ..with Gold multi-IQ on .. / 10khz-80khz / technology... It's just my rough estimate of development ...
  15. GB Amater .. in the summer darkened my display from high temperature in the summer above 40 degrees Celsius in Spain, because I left the detector in the field in the sun for quite a long time lying ..... But everything returned quickly to normal ... after a slight lowering the detector temperature in the shade. Regarding a recurring reset at Equinox ... I would try to connect the detector to a powerbank ... and test the Equinox Stability like that .. If there is a connection error at the detector coil itself ... then the detector should turn itself off ...
  16. Even though there was somewhat different opinion from minelab Vanquish 340 users on how well this detector can detect in the iron and divide these views into two groups of views. some are very satisfied with the detectors.......and also those users for whom this detector has only average separation properties.... My latest comparison of Vanquisha in the "Monte" nailbord separation test on a low conductive 5 gram nickel coin and a 5 gram high conductive silver coin revealed the fact .... both sides are right. Detetkor Vanquish 340 -a V10 coil I tested on all 3 programs..Allmetal, Jewerly, and also Coin program. The results of the separation test are surprising. The 5 gram silver high-conductivity coin gained only a "Average result" in the nailbord test .... 5.5 points of 8 point max...! 5 grams of nickel low-conductivity coin got " excellent result" in nailbord test 7.5-8 points out of 8 points Max .. !!! This detector is excellent for separating low conductive objects .... !!! The detector worked best on separation in All metal y Jewerly ...Jewerly program in some cases ... it helps better to highlight good signal between iron and iron than Allmetal ....but I wouldn't take it as a rule, rather as an alternative ... for a better verification of a suspicious signal .. The Coin program was significantly weaker in the separation. .
  17. Steve .... can you write a more detailed review of Whites Goldmaster 24K ...and add your individual coils view to this detector?
  18. Rivers rat.... Spectra V3 is designed as a multi-frequency detector with a multi-frequency that has a smaller range than the Spectra mode operating on only one frequency ... From a practical point of view, such a multi-frequency, even if it is not as deep as possible on a slightly mineralized soil. ..and here the advantage of being able to work very well on a wide range of terrain mineralization .. while having a balanced detection range on all kinds of conductivity of the object .. even in relatively heavily mineralized terrain ... its main advantage ... However, the maximum detection range can be increased quite simply by using a larger size coil such as a standard 10 "coil, for example, a 12x10" sef coil achieves good results ... and a 12 "or 13" coil gives you even better depth. if the terrain allows you to also use TX bost .... which can, for example, compensate the depth difference Sef 12x10 "coil versus 13" round coil - that's the difference in range on a very deep a medium coin size target .. about 3-4 cm ... Spectra also becomes a deep detector in multi-frequency. Spectra has a lot of settings ,,,, but in practice use and change a maximum of 3-4 settings according to the type of detection and terrain .. ----------------------------------------------------------------------------------------------------------------------------------------------- Spectra V3 on 13 "coil ... reaches the prerequisites for deep detector ..
  19. Spectra V3 ... the detector is like a "Rolls-Royce ".....quality metal ... and... high quality piece of Analog and Digital detection technology and embedded engineering thinking ..., the color display of this detector has never surpassed ... Choose the right coil for the detector and Spectra can truly .. excellently and deeply detect ... The weight of the detector ... with a lithium acu-pack and a 6x10 "Sniper coil I feel that this detector is well balanced and feels relatively lightweight .. really lightweight .... On 13 "and 18" coil ... on straight shaft .... again metal box in the back ..still provides relatively good balance even when detected with relatively heavy coils ... 700-1050 grams ... Keeping the original ... the possibility of software update of the detector as the was planned this detector would become very good....polished ..." diamond ".. I agree with Mike ... that's why I have 2 x whites Spectra ... V3... and ...V3i ... ..I still believe in Whites can come up with a new Spectra .. Because the world and detection technology also goes further .... I even expect it ... ------------------------------------------------------------------------------------------------------------------------------------------------ Spectra V3 -18"DD excelerator II coil..+TX Bost...
  20. I would like to supplement this test with a field test Tarsacci MDT 8000 from Keith Southern.👍---------------------------------------------------------------------------------------------------------------------------------------------------
  21. Today afternoon ... after work I did a short comparison of my Teknetic G2 detector separation on 13 "Ultimate coils and also a small 3.5x 7" coil Nel Snake / cors chrew / .. in my standard deep and separation test .. Detector setting :, sensitivity 100, discrimination 40 .. Results of depth and separation: Teknetics G2 + .. 13 "Detech Ultimate Coil .... has reached 4-to 4.5 points out of 8 max. On this large 13 "Ultimate coil you really only get the average separation .. But deep profits increase by 3-5 cm compared to the Standard 11 "DD coil ... for targets like small and medium sized coins .. /up to 23cm for small/13mm silver hammered/ ..and up to 35cm for medium sized /50eurocent/ coin..-but it is already a border signal with ID... Tek G2 + ..3.5x 7 "Nel Snake Coil ... achieved excellent separation results ... 7.5-8 points out of 8 max ... and works great with this detector in the iron. The depth of detection will be up to 14cm.. for small/ 13mm hammered/coin-...and up to18 cm on medium sized/50eurocent/ coins ...
  22. I give this info here only for demonstration, that the coil for Vanquish can be bought separately ...I'll delete those links in an hour ...
  23. Equinox in its basic programs focused on great stability and the elimination of coke and also black smoke ceramics .. .., therefore it has default discrimination and also tone break up to + 1, + 2 ID ... Programs set up this way ... but are not set to the best level of separation in the iron ... but only the average separation that Equinox can achieve on the 11 "coil. And just this YT video-the Tuomas Koivurova ..points out why ... it's not just good to work on Equinox core programs ... Experienced Equinox users can customize these programs according to their needs .. and achieve above-average separation. As for the separation between Deus on the 9 "coil and Equinox on the 11 coil" each of these detectors unmask their part of the targets ... But a really fair comparison would only be in that case ... if Equinox also had the same 9 "round coil as Deus .. And then we can say .. The king is dead ... Long live the king !!!
  24. SlavoM777Hace 2 años Equinox -Tone break is set to 2 in the Field 2 program, changed to 0, and open the Discrimination Accept -2 to 40 ... and this test goes to Recovery sped 5,6,7,8 ... Vanquish 340 does not pass this test, maybe even because of my small 7 "V10 coil .. . But according to me ..... the 9" V12 coil should work better in this test ..
  25. Vanquish ... was a really challenging task for Minelab because optimizing the detector for a customized multi-frequency multi-IQ program (beach type1) for a variety of environments and detection conditions requires a lot of effort..and it's not easy .... advantages of this technology .. ID quality in depth .., and working in various terrain mineralization .. It is also almost impossible to prove that Multi-IQ technology has been promoted in this price range ... because multi-frequency detectors have always been expensive in the past. I believe that this Multy-IQ technology will be further improved.
×
×