  1. Today I am in a test to eliminate Iron .. also came with Equinox 800-6 "coil several 0.17 pellets with ID 3 and one 0.22 with ID 4-5 ...
  2. ...Today I was passed the Equinox 6 "coil on my Carbon Telescopic shaft, on my" clean terrain, and I started Test 1-"determination of Iron" to compare the work of the Park 2 main program and the iron control of the Beach 2 program stored in the User profile .. at high sensitivity 23 .. I compared the signals with ID 15-17 before digging with a fine iron tone, which, after checking in the Beach 2 program, clearly pointed to id -6 and the pure iron tone ... which after the excavations turned out to be old nails ... Another comparison Test2 -"identifikation nonferous" was found in the Park 2 signal program with positive IDs with a bit of iron signal that would be in line with the Beach2 ID and then dig it ... I dug a few pieces of colored metal .. so I have the impression of reliably getting enough of this test. .My program Park2 settings: sensibility 23, allmetal,recovery speed 7,iron bias 0-1,. For control Iron- In user profile: program Beach 2,sensibility 23, allmetal ,recovery speed 8, and iron Bias 9.. It's during the test 1. - the nails in the ground - in Park 2 I have been trying to reduce the sensitivity from 23 to 15 to lower to get some better signal on iron and less signal for colored metal .. - but it was also not ideal. Continue in 2 tests to see from program Beach 2 did not have the problem to show a good ID for such a small shot-pelet in the ground ..Photo on left side test1- determination of iron-is pulled out of iron ... on the right side Test 2 on the truth of identification of non-ferrous metal ...3 pellets and piece of metal ..
  3. Another step forward - how to use the Signal probe function to repair a coil that is out of signal tolerance ... I degraded the signal value below half the value and removed the overload ...
  4. ... in the test firmware for Equinox... it was also possible to set the pinpoint power ... I would appreciate the possibility in another update ...- to set it up as a very weak signal, or not on a very deep coin ....
  5. So, and the telescopic carbon shaft is home. The Equinox is 57 cm long for comparison,the weight is 1224 grams of 6 "coil..
  6. I also found some coins in the iron that I had a partial iron signal and ID 16,17 to 21,22 - but I decided to dig it after the first such digged coin - I'm more careful ...., I can find me more this signal from the coin ...- I know definitely need to feel more audio signal Equinox ...
  7. The Iron Bias setting also influences: 1.Of the detector frequency used, or the multifactor program weights, 2. the set recovery speed ...,. 3 Detector Discrimination Used. and also 4. detector sensitivity adjustment ... Now you can select -A: Do you want to increase the separation and unmasking of the detector in the iron? .. or B-do you want to discern iron-plated bottle cap caps? ... If you want to maximize the separation-A give the frequency, the multifrequency program type Park 2, the high recovery speed, the less or no dyscrimination, and less the sensitivity of the detector ... If you want to determine what is a ferrous waste- B, use a low frequency, a low power, low-frequency Beach 2 program to scale!, increase the iron bias to the maximum !,recovery speed high 7-8-!-its less sensible for, tini,or plated metal.. , increase the discrimination setting- !, and decrease the sensitivity...
  8. ... it's 28mm , .. I have a golden mask with these carbon shaft ... such a set to adjust handle to shaft Golden Mask is for sale ...I already ordered one .. I write more about it .. when it comes ..
  9. On my modified carbon rod I used a 1 Nylon pad to define the size of the coil attachment .. it is better than the thicker rubber base ...
  10. ...if the detectorist are sufficiently interested in the concentric coil -that it definitely passes through the marketing department of minelab, it is a good opportunity - competitors do not have it.,,.. it is important to agree whit the appropriate size of the concentric coil ...5",6",7"?
  11. ... an expanded assortment of coils is a very good idea for Equinox - it can help you reach a large number of potential users ... Equinox has a good number of programs and settings that you can optimize to work on a given coil size ...
  12. I'm on a high recovery rate, it's 6 better to figure out the size of the subject ... like the recovery speed 4 ... here's the signal longer and it's more compact-less readable ... for me, sometimes I switch to 5khz-a more iron signal ... ID is also run-less firmly ... Equinox has a feature with a optic overload indicator in only one program on Beach2 - and there is a TX execution ..- I try to do it in the - user profile program and compare it ..
  13. When I compared the ALLmetal and Discrimination modes in the 6-inch coil, I pulled the sensitivity up to the level when I feel weak, but regular signal on 13.5 mm -0.54 gram silver Denar coin -is buried at 23cm in the ground ... I got the sensitivity of 14th to Allmetal mode as also at Dyskrimination mode... program Park2, recovery speed 4 ... Signal without ID but clear and regular signal on nonferous metal ...Equinox has very good signal processing...All metall me also definitely outweigh discriminative-better capture signal -If the coil is not exactly above the deep target...like as a mini mix mode...
  14. Separation....6 "coil has a about 3cm wide- snapshot RX window -it helps,, .. 11" has RX window wide 4.5cm ...Test - when I compared it a quick separating 6 "coils - I put in one row 6-7 pieces 10-eurocent coins per 1.5cm from each other .. and increased recovery speed - at 4 is in this test . relatively slow .. but at 6,7,8 it's gatling ... ..I was surprised , how fast is Equinox ...
  15. small Super D coil - for VLF, should not be a big technical problem ..
  16. CC-coil -I'm thinking about this idea a few days ago, even in terms of ID of iron undesired waste ... "From my observation 6" equinox coil on targets 1 grain- range 3 ", standard coil 11" - range 2 " with the same sensitivity-20 ... program park 2, .... Is there also the possibility of a small coil-DOD-super D coil ...
  17. Profind 35 is set at 3 as sensitive as Profind 25 when set to max. When I dropped profind35 to max sensitivity-6 setting, it proved me to detect the thinness of 3.3mm diameter -0.062gram of a small piece of lead at a distance of -4mm from the tip, 4.3mm diameter -0.11gram piece of lead-at a distance of 8mm, and .. 5.6mm-0.37gram piece of lead-at a distance of 20-22mm ... Clearly in terrain it is more difficult to find...
  18. Sometimes I like to find where I've ever been and find something new again. Sometimes it's just one coin a day .. foto-Return with Equinox...
  19. Equinox is specifically a detector with very good signal processing, it is very strong on the 11 "coil and also very strong on 6 "coil- and low sensitivity 14 ...- if you work as an analog detector only 2- tons ... without ID -incredibly deep.. .... today I compared the sensitivity and depth of allmetall mode and discrimination .. If you compare SEF12x10 with 10dd to Spectra V3 ... so I can not believe the coil 12x 15 for equinox will be deeper than standard 11 "-that will mat long window of scan ...
  20. I've also had a problem in winter when it was below zero. If the temperature is above zero degrees C, then I have no problem ... IN winter temperature was below zero Celsius - I only used vibration ..
  21. there's something to motivate - replacement battery pack li-ion 18650 and battery dimensions - so it will not be a problem to do 4x 18650, or 6X 18650 ... maybe even more ...
  22. You can use a stronger preamp -rx in the -gold 2 program, and it may be slightly changed Sat, and the frequency can be bridged as in the gold 1 program, what changes in the recovery speed - whether you are Gold2 optimized for recovery speed 4 - but I would be glad if someone also verified it....
  23. I use the coil mars sniper-6X10 "on the Whites Spectra V3-it's an excellent, and sensitive multifrequency coil, so I do not doubt the similar coil on the Equinox will be just as good ... it had 6 equinox" coil is already at home but momentarily I'm a week out in Spain...
  24. Thanks for test,,,small coil - we can also use the lower recovery speed, so the results can be similar...
×
×